furnace flame goes out when blower comes on

Why Won't My Furnace Flame Stay on When Blower Runs

By Andrew Taylor
AD

Ever noticed your furnace's flame flickering and extinguishing just as the blower turns on? You're not alone in this troubling HVAC predicament. This issue can be perplexing and potentially dangerous, so let's dive into the causes, solutions, and tips to help you restore your heating system's normal function.

Before we get into the nitty-gritty, let's ensure you're dealing with the correct scenario. Make sure that your furnace indeed turns on, and the igniter glows, but the flame extinguishes when the blower engages. If your furnace isn't igniting at all, that's a different issue entirely.

Understanding the sequence of events

The furnaces we're discussing are conventional, non-condensing models. In these systems, the blower fan typically comes on before the burners to create negative pressure inside the combustion chamber. This ensures proper draft and prevents carbon monoxide backdraft. Once the burners ignite, the blower continues running to distribute heated air throughout your home.

AD
Furnace Flame Goes Out When Blower Comes On
Furnace Flame Goes Out When Blower Comes On
4 Reasons Why Your Furnace Blower Starts & Then Stops Immediately
4 Reasons Why Your Furnace Blower Starts & Then Stops Immediately
Home Services
Home Services

So, something's amiss when this sequence is disrupted, and the blower's onset snuffs out the flame. Let's explore the potential culprits.

Pressure imbalances in the heat exchanger

Pressure imbalances within the heat exchanger can cause insufficient oxygen supply to the burners, causing the flame to extinguish. This could be due to excess negative pressure caused by a faulty inducer or blower motor, or a leak in the heat exchanger itself.

the reflection of two cats in a mirror
the reflection of two cats in a mirror
4 Reasons Why Your Furnace Blower Starts & Then Stops Immediately
4 Reasons Why Your Furnace Blower Starts & Then Stops Immediately
How to Fix Furnace Blower
How to Fix Furnace Blower

To troubleshoot, check the inducer motor and blower motor for proper functioning and replace them if necessary. For heat exchanger leaks, it's best to hire a professional HVAC technician, as repairing or replacing the heat exchanger can be complex and risky.

Draft inducement issues

Problems with draft inducement can also lead to this problem. If the furnace's draft inducer isn't working correctly, it may not create enough negative pressure to draw combustion air into the burners. This can cause the flame to extinguish when the blower comes on,starving it of oxygen.

AD

Inspect the draft inducer motor and ensure it's functioning properly. You may also need to clean the inducer to remove any accumulated soot or dust blocking the airflow. If the inducer motor is faulty, replace it with a compatible part.

Furnace Blower Motor: How Much Is It to Replace?
Furnace Blower Motor: How Much Is It to Replace?
How To Adjust Blower Speed On Goodman Furnace
How To Adjust Blower Speed On Goodman Furnace
Furnace does not work on very cold mornings because big...
Furnace does not work on very cold mornings because big...
When your furnace stops working in the middle of a cold London winter, every hour counts. At Hawana
When your furnace stops working in the middle of a cold London winter, every hour counts. At Hawana
Furnace won't blow heat Locust Grove
Furnace won't blow heat Locust Grove
Dirty Furnace Flame Sensor
Dirty Furnace Flame Sensor

Other possible reasons and their solutions

While the primary focus is on pressure imbalances and draft issues, other problems might be at play. Let's explore a couple more potential causes and their remedies.

Damaged or dirty flame sensors can prevent the burners from igniting or cause repeated cycling, leading to flameout. Clean the flame sensor with a fine-grit (e.g., #000) steel wool or replace it entirely if it's damaged.

AD

Furnace and ductwork leaks

Leaks in the furnace or ductwork can disrupt proper airflow and pressure, leading to flameout. Inspect the furnace cabinet, ductwork, and corresponding connections for any gaps or tears. Seal any leaks using mastic or UL-listed ducts. Ensure that the ducts aren't overwhelmed by the blower's outflow by checking the ductwork size and furnace blower compatibility.

10 Reasons a Blower Fan Won't Start in a Furnace, AC or Heat Pump
10 Reasons a Blower Fan Won't Start in a Furnace, AC or Heat Pump
Lower Home Heating Costs - Fireplace Blower Benefits
Lower Home Heating Costs - Fireplace Blower Benefits
a large metal object in the middle of a fire filled cave with flames coming out of it
a large metal object in the middle of a fire filled cave with flames coming out of it
Furnace Not Blowing Air Through Vents? Top 4 Causes + Fixes
Furnace Not Blowing Air Through Vents? Top 4 Causes + Fixes

If you're unsure about any part of this troubleshooting process, or if your efforts to resolve the issue aren't successful, don't hesitate to call a professional HVAC technician. They have the tools and expertise to accurately diagnose and fix problems with your furnace. Regular professional maintenance can also help prevent issues like this in the future.

In most cases, addressing pressure imbalances, draft inducement issues, and other potential causes can resolve the problem of your furnace's flame extinguishing when the blower turns on. Stay safe this heating season by being proactive about your furnace's wellbeing, and don't hesitate to seek help when you need it.

AD
AD